{"product_id":"clipsal-max-4-miniature-circuit-breaker-3p-16-a-c-curve-6000-a-415-v-4cb316-6","title":"Clipsal Max 4 Miniature circuit breaker 3P 16 A C curve 6000 A 415 V | 4CB316\/6","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003eAll miniature circuit breakers are sourced from leading Australian suppliers with an impressive range of MCB's to suit local conditions and requirements. They all have the relevant approvals and meet all applicable Australian\u003c\/span\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cspan\u003eThis Clipsal Series 4 product is a low voltage miniature circuit breaker (MCB). It is a 3 circuit breaker with 16A rated current and C tripping curve. The rated short circuit breaking capacity is up to 6kA at 415VAC conforming to EN 60898 standard. This product is compliant with AS\/NZS 60898 standard. This miniature circuit breaker combines functions of circuit protection against short circuit and overload current, control and isolation. Mechanical durability goes up to 20000 cycles and electrical durability goes up to 20000 cycles. The Ue operational voltage is 415VAC. It can be mounted on DIN rail for modular installation. Its width is 6 pitches of 9mm. The dimensions are (W) 54mm x (H) 81mm x (D) 78.5mm. The weight is 310g. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -25°C to 70°C. The storage temperature is -40°C to 70°C.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"col-6 pr-5 px-lg-3\"\u003e\n\u003ctable class=\"table table-borderless\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eDegree of protection (IP)\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eRated short-circuit breaking capacity Icn according to EN 60898 at 400 V\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e6 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eNumber of poles (total)\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eBreaking capacity\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e6 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eFlush-mounted installation\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eVoltage type AC-DC\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eRated current\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e16 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eCurrent limiting class\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eBuilt-in depth\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e73 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eRelease characteristic\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eConcurrently switching neutral conductor\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cimg title=\"V1202-9318795014005\" alt=\"V1202-9318795014005\" style=\"display:none\" src=\"https:\/\/services.dropshipzone.com.au\/admin\/api\/public\/images\/logo.png?sku=V1202-9318795014005\u0026amp;rid=2932\"\u003e\u003cdiv class=\"col-6 pl-5 px-lg-4\"\u003e\n\u003ctable class=\"table table-borderless\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth colspan=\"2\"\u003e \u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eConnectable conductor cross section solid-core\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e0.75 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eFrequency\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e50 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eConnectable conductor cross section multi-wired\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e0.33 mm²\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eWidth in number of modular spacings\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eNumber of protected poles\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eAmbient temperature during operating\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e-25 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eRated voltage\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e415 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eRated insulation voltage Ui\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003e440 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eAdditional equipment possible\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-bottom\"\u003e\n\u003cth scope=\"row\" class=\"bg-panel break-word font-weight-normal width-60\"\u003eMounting method\u003c\/th\u003e\n\u003ctd class=\"font-weight-bold break-word width-40\"\u003e\u003cspan class=\"tech-table-values-text\"\u003eDIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Shopperslane","offers":[{"title":"Default Title","offer_id":49073047306492,"sku":"V1202-9318795014005","price":102.49,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1299\/5883\/files\/V1202-9318795014005-00.webp?v=1778102563","url":"https:\/\/www.shopperslane.com.au\/products\/clipsal-max-4-miniature-circuit-breaker-3p-16-a-c-curve-6000-a-415-v-4cb316-6","provider":"ShoppersLane","version":"1.0","type":"link"}